Current to Pressure Transducer
Intrinsically Safe, NEMA 4X Enclosure, Field Reversible, Low Cost



The Series IP Current to Pressure Transducer converts a current input signal to a linearly proportional pneumatic output pressure. The features include built-in volume booster, low air consumption, field reversible (provides output which is inversely proportional to the input signal) and flexible zero and span adjustments. The rugged NEMA 4X enclosure allows splashdown and outdoor installation. The IP can be used for applications that require operation of valve actuators, pneumatic valve positioners, damper and louver actuators, final control elements, relays, air cylinders, web tensioners, clutches and brakes.

STOCKED MODELS in bold

Model Number Input Ranges Output Range
psi kPa
IP-42 4-20 mA 3-15 20-100
IP-43 4-20 mA 3-27 20-185
IP-44 4-20 mA 6-30 40-200

PHYSICAL DATA
Supply Pressure: Minimum: 3 psig (21kPa) above maximum output; Maximum: 100 psig (700 kPa)
Pressure Connections: 1/4" female NPT.
Electrical Connection: 1/2" female NPT.
Output Capacity: 4.5 SCFM (7.6 m³/h ANR) at 25 psig (175 kPa) supply; 12 SCFM(20 m³/h) at 100 psig (700 kPa) supply.
Relief Capacity: 2 SCFM (3.4 m³/h) at 5 psig (35 kPa) above 20 psig (140 kPa) setpoint.
Maximum Air Consumption: 0.03 SCFM (0.5 m³/h) typical.
Media: Oil free, clean dry air filtered to 40 microns.
Weight: 2.1 lbs. (0.94 kg)
ELECTRICAL
Input Signal: 4-20 mA
Input Impedance: IP-42: 180 ohms; IP-43 and IP-44:220 ohms.
PERFORMANCE
Supply Pressure Sensitivity: <±0.1% of span per psig (<±0.15% of span per 10 kPa)
Repeatability: <±0.5% of span
Linearity: <±0.75% of span
Hysteresis: <±1% of span
Operating Temperature Range: -20 to 140°F (-30 to 60°C)